| Differences are marked in red | M453 PCIe 4.0 NVMe M.2 500GB | M453 PCIe 4.0 NVMe M.2 1TB | M453 PCIe 4.0 NVMe M.2 2TB |
|---|---|---|---|
| Model Name | M453 PCIe 4.0 NVMe M.2 | M453 PCIe 4.0 NVMe M.2 | M453 PCIe 4.0 NVMe M.2 |
| Capacity | 500GB | 1TB | 2TB |
| Controller | PHISON E19T | PHISON E19T | PHISON E19T |
| Flash Memory | 3D NAND | 3D NAND | 3D NAND |
| Form Factor | M.2 2280 | M.2 2280 | M.2 2280 |
| Interface | PCIe Gen4x4, NVMe 1.4 | PCIe Gen4x4, NVMe 1.4 | PCIe Gen4x4, NVMe 1.4 |
| Compatibility | PCIe Gen4/ Gen3 / Gen2 / Gen1 | PCIe Gen4/ Gen3 / Gen2 / Gen1 | PCIe Gen4/ Gen3 / Gen2 / Gen1 |
| Dimensions | 80.00mm (L) x 22.00mm (W) x 2.15mm (H) | 80.00mm (L) x 22.00mm (W) x 2.15mm (H) | 80.00mm (L) x 22.00mm (W) x 2.15mm (H) |
| Sequential Read up to (MB/s) | 3600 | 3600 | 3600 |
| Sequential Write up to (MB/s) | 2400 | 2800 | 2800 |
| Random Read 4KB up to (IOPS) | 400,000 | 500,000 | 500,000 |
| Random Write 4KB up to (IOPS) | 550,000 | 550,000 | 600,000 |
| Maximum Operating Power (W) | 4.8 | 4.8 | 4.7 |
| Idle Power PS3 (mW) | 40 | 40 | 40 |
| Low Power L1.2 (mW) | 5 | 5 | 5 |
| Operating Temperatures | 0°C – 70°C | 0°C – 70°C | 0°C – 70°C |
| Storage Temperatures | -40°C – 85°C | -40°C – 85°C | -40°C – 85°C |
| Terabytes Written (TBW) | 300 | 600 | 1200 |
| Mean Time Between Failure (MTBF) | Up to 1,500,000 Hours | Up to 1,500,000 Hours | Up to 1,500,000 Hours |
| Limited Warranty | 5 Years, or the coverage for the maximum TBW as stated, whichever comes first. | 5 Years, or the coverage for the maximum TBW as stated, whichever comes first. | 5 Years, or the coverage for the maximum TBW as stated, whichever comes first. |
| Advanced Features | TRIM (Performance Optimization, OS Support required)<br /> SMART (Self-Monitoring, Analysis and Reporting Technology)<br /> LDPC (Low Density Parity Check) ECC Algorithm<br /> End to End Data Path Protection<br /> APST (Autonomous Power State Transition)<br /> Pyrite (Encryption, Data Security) | TRIM (Performance Optimization, OS Support required)<br /> SMART (Self-Monitoring, Analysis and Reporting Technology)<br /> LDPC (Low Density Parity Check) ECC Algorithm<br /> End to End Data Path Protection<br /> APST (Autonomous Power State Transition)<br /> Pyrite (Encryption, Data Security) | TRIM (Performance Optimization, OS Support required)<br /> SMART (Self-Monitoring, Analysis and Reporting Technology)<br /> LDPC (Low Density Parity Check) ECC Algorithm<br /> End to End Data Path Protection<br /> APST (Autonomous Power State Transition)<br /> Pyrite (Encryption, Data Security) |